Name: Smart Logger

Text: SMART LOGGER
Multi-channel call recording and monitoring system.
Hardware

Applications
Logging and monitoring:
u Telephone conversations
u Facsimile transmission sessions (using Fax
Reader module)
u Radio conversations (using noise cancellation
feature to improve intelligibility)
u Acoustic signal from any source
Used by:
u Police, Military & National Security Forces
u Security & Emergency Services
u Public Safety Service Centers
u Call Centers & Help Desks
u Legal, Financial& Insurance Institutions
u Governmental Institutions
u Air Traffic Control Sites
u Medical Institutions
u Any organisations that depend on verbal
communication

Advantages
u
u
u
u
u

u
u
u
u
u
u
u

u
u

Reliable (24-hour continuous work) & easy-touse
Portable, industrial & desktop configurations
Perfect sound quality (up to 75 dB sound-tonoise ratio)
Noise cancellation module for increasing speech
clarity and playback comfort.
Analog phone line recording through a telephone
interface with non-galvanic coupling to the line
with high input impedance
ISDN S0, E1 digital phone line interfaces
Supports all major PBX manufactures: Tadiran ,
Siemens, Philips, Nortel, Lucent, Ericsson.
Multi-level access restriction
Network integration for a large scale systems
Comprehensive search capability
Text transcription module, view, export and other
operations with recordings
Automatic & manual scheduled archiving on
different types of removable media (DVD-RAM,
MO, DVD-RW,CD-RW)
Automatic fax decoding
Network LAN system and remote control through
modem module

u
u

u
u

4/8 channel STC-H197/205 boards with telephone
interface
6 channel STC-H199 board with digital lines
interface (STC-H195 adapter is included for
connecting to digital lines)
ISDN PRI E1 system
All systems include
- Smart Logger software
- Documentation
- Cables and connectors, manuals

Additional Options
u Remote control through modem software module
u Additional playback set based on professional STC
sound card or on Sound Blaster compatible card
u Fax Reader facsimile decoding module

Features
u

u
u
u

u

u

Technical Specifications

u
u

u

u
u
u
u
u
u

u

u
u

u

u

Smart Logger is available as a scalable
distributed Network system for call-centers and
as a portable system for field applications.
Sampling rate: 8-16 kHz
Sound storage: 128 Kb/s, 64 Kb/s PCM(u-Law),
32 Kb/s ADPCM,16 Kb/s ADPCM
Hard Drive consumption per hour (8 kHz
sampling rate): 58 Mb, 29 Mb,14 Mb,7 Mb
Signal/noise ratio: >75 dB for 128 Kb/s bit rate
Non-linear distortions: <0.1%
Gain control: input automatic gain control, output
automatic digital gain control, adjustment range
up to 50 dB, option to turn off AGC
Recording triggers: voice activation, On/Off hook
detection, activation by external sensor,
activation by control signals
Access restriction: 4 levels of password system
Supported facsimile protocols by Fax Reader II:
V.27-ter,V.29,V.17;T.30,T.4,T.6 (standards of the
International Telecommunications Union ITU)
Environmental Conditions: Operating
temperature: 5 -40 deg C; Storage temperature:
-10 -60 deg C; Humidity: 85% RH(noncondensing) at 40 deg C
Requirements: PC configuration: Pentium III or
higher, RAM - 32Mb, HDD>2Gb, MS Windows
95/98/Me and NT/2000.

u
u
u
u
u
u
u
u

u

u
u

All recordings are stored in sound database
indexed by date, time, duration, channel number,
keywords, DTMF codes, comments
Database is equipped with sorting and filtering
functions
Access to sound database via LAN and dial-up
connection
High quality recording with or without
compression allowing further procedures over
sound such as speaker identification, noise
filtering or other signal processing
Telephone interface is galvanically separated
from the line and has high input impedance to
prevent detection
DTMF codes, CallerID and other service signals,
pulse dialed numbers recognition
Playback of recorded signals without recording
process interruption
Built-in convenient tool for text decoding of
recorded speeches
Selectable playback speed without voice pitch
distortion
Linking between the typed text and the
corresponding sound fragment
Instant access to any previously recorded sound
or typed text
Sound data export in *.WAV (Windows) or
*.DAT(STC/SIS) format
Operator control is optional
Distributed LAN configuration for call-centers,
emergency services and police
All possible service for the speech
communication channels monitoring team
Supervision of a number of logging workstations
can be done by one system administrator in
Smart Logger Network System
Automatic on-the-fly tuning of the recording
settings (threshold adjustment for line and call
status, voltage measurement)
Background auto fax decoding with Fax Reader
module. Auto printing of the decoded faxes.
Optional Sound Blaster compatible playback
workstation

Smart Logger Working Window with
Waveform Viewer open

Typical Configurations
Smart Logger system has an open scalable
architecture allowing different configurations for every
task. Some configurations samples :
Configuration Example A: 4 channel analog
telephone line recording and monitoring station
Smart Logger recording server configuration:
Pentium III system containing professional PCI STCH197 board with telephone interface, “Smart Logger
4” software, manuals and cables.

u

u Configuration Example B: 16 channel analog
telephone line recording with auto fax decoding
and remote monitoring
Smart Logger configuration:
Recording server: Pentium III system with network
adapter containing 2 professional PCI STC-H205
boards with telephone interface, Smart Logger
software, Fax Reader II software, Remote control via
LAN software module, manuals and cables.
Remote monitoring workstation: Pentium III system
with Smart Logger additional playback software,
manuals and cables.
Recording server and remote monitoring workstation
are connected via LAN to allow remote line monitoring
and access to the server database.

Configuration Example C: E1 digital 30 channel
recording solution
Smart Logger recording server configuration:
Pentium IV system containing 1x STC-H199_01
board and, if necessary, additional device/adapter,
Smart Logger software, manuals and cables
u

Recordings Search & Filtering
dialog box of Smart Logger

Configuration Example D: Digital extensions 6
channel recording solution for PBX
Pentium III and above system containing
professional STC-H199 digital board, Smart Logger
software, manuals and cables.
u

Configuration Example E: 3 ISDN recording at
site A, 6 ISDN recording with auto fax decoding at
site B, Remote monitoring via modem from site C
Smart Logger configuration:
1 Recording server at site A: External adapter
providing undetected parallel connection to 3 ISDN
lines, Pentium III and above system with modem
containing 1 professional STC-H199 digital board,
Smart Logger software, Remote control via modem
software module, manuals and cables.
2 Recording server at site B: External adapter
providing undetected parallel connection to 3 ISDN
lines, Pentium III and above system with modem
containing 2 professional STC-H199 digital boards,
Smart Logger software, Fax Reader software,
Remote control via modem software module,
manuals and cables.
Remote monitoring workstation at site C: Pentium III
and above system with modem and Smart Logger
additional playback software, manuals and cables.
u

Remote monitoring workstation at site C initiates
modem connection to the recording servers A or B
providing remote access to the server's databases.

Smart Logger Working Window with
Fax Reader Module open

Sample Configuration of Distributed LAN Smart Logger System

PBX or PSTN

Recording stations

Archiving
server

Administration
workstation

LAN

E1, ISDN, analog to
extensions or
external channels

Operator workstation with
fax decoding system

Remote operator
workstation

Document Path: ["1140-speech-technology-center-brochure-smart.pdf"]

e-Highlighter

Click to send permalink to address bar, or right-click to copy permalink.

Un-highlight all Un-highlight selectionu Highlight selectionh