Name: Monitoring Center

Text: Siemens MC General Product Description V2.3.doc Page 1 of 48
Copyright © Siemens AG 1999, 2000
ICM CD IS (Information Security)

GENERAL PRODUCT DESCRIPTION
SIEMENS MONITOR CENTER

Siemens MC General Product Description V2.3.doc Page 2 of 48
Copyright © Siemens AG 1999, 2000
ICM CD IS (Information Security)

Table of Contents
1. SCOPE.............................................................................................................5
1.1. IDENTIFICATION ..................................................................................................... 5
1.2. PURPOSE ................................................................................................................ 5

2. DEFINITIONS ..................................................................................................6
2.1. MONITOR CENTER................................................................................................. 6
2.2. MONITORING........................................................................................................... 6
2.3. GENERAL DEFINITIONS......................................................................................... 8

3. DESIGN OVERVIEW.....................................................................................11
3.1. HIGH LEVEL DESIGN............................................................................................ 11
3.2. GEOGRAPHICAL DISTRIBUTION........................................................................ 12

4. MONITOR CENTER FRONT­END: GENERIC...............................................13
4.1. FRONT­END: PASSIVE MONITORING ................................................................ 14
4.1.1. Passive Monitoring Front­End components .................................................... 15
4.1.1.1. Acquisition Units, Recorders (AQ) ............................................................... 15
DVX – Switching Multiplexer ......................................................................................... 16
4.1.1.3. Protocol Analyser (PA) ................................................................................. 17
4.1.1.4. Recording Controller (CTRL)........................................................................ 18
4.1.1.5. Supervisor Station (SVR) ............................................................................. 18
4.2. FRONT­END: ACTIVE MONITORING................................................................... 19
4.2.1. General............................................................................................................. 19
4.2.1.1. Dual Route Interfaces (DRI) ......................................................................... 21
4.2.1.2. Single Route Interface (SRI) ........................................................................ 22
4.2.2. Statistical Monitoring ........................................................................................ 22
4.2.3. Active Monitoring Front­End components ....................................................... 23
4.2.3.1. Acquisition Unit ............................................................................................. 23
4.2.3.2. Call Controller (CC)....................................................................................... 24
4.2.3.3. S­Record­Controller (LI­Rec.­Contr.) ........................................................... 24

5. MONITOR CENTER BACK­END...................................................................25
5.1. BACK­END FUNCTIONALITY ............................................................................... 25
5.1.1. Dossier based administration: ......................................................................... 25
5.1.2. Dossier based archiving of intercepts:............................................................. 25
5.1.3. Dossier based access to the intercepts:.......................................................... 25
5.1.4. Hot / On­line Monitoring: .................................................................................. 25
5.1.5. Processing of intercepts:.................................................................................. 26
5.2. BACK­END COMPONENTS .................................................................................. 26
5.2.1. Principle Overview............................................................................................ 26
Management Station / Supervisor Station for EWSD...................................................... 27

5.2.2.1. Supervisor Station for EWSD....................................................................... 27
5.2.2.2. Dossier Administration / MC Manager ......................................................... 27
5.2.3. MC Controller (MCC)........................................................................................ 29
5.2.4. MC Database ................................................................................................... 30
5.2.5. Storage System / Dossier Storage .................................................................. 31
Siemens MC General Product Description V2.3.doc Page 3 of 48
Copyright © Siemens AG 1999, 2000
ICM CD IS (Information Security)

5.2.5.1. Export of data from Dossier Storage............................................................ 32
5.2.5.2. Management of storage volumes ................................................................ 32
5.2.5.3. Restoration of data ....................................................................................... 33
5.2.6. Operator Station / Unified User Station ( UUS ) .............................................. 34
5.2.6.1. Playback ....................................................................................................... 35
5.2.6.2. Hot / On­Line Monitoring .............................................................................. 35
5.2.6.3. Fax Display ................................................................................................... 36
5.2.6.4. Transcription ................................................................................................. 36
5.2.7. Fax and data Demodulation............................................................................. 37
5.2.7.1. Siemens Fax Demodulator........................................................................... 37
Fax/Data Demodulation System................................................................................... 38
5.2.7.3. Manual or automatic data analysis............................................................... 39

6. ALARMS........................................................................................................40
7. EVENT LOGGING .........................................................................................41
8. MC SECURITY...............................................................................................42
8.1. DOSSIER STORAGE FILE SECURITY................................................................. 42
8.2. DATABASE SECURITY ......................................................................................... 42
8.3. PHYSICAL SECURITY........................................................................................... 42

9. SCALABILITY................................................................................................43
10. RELIABILITY...............................................................................................44
10.1. SYSTEM TIME..................................................................................................... 44
10.2. POWER SUPPLY................................................................................................ 44
10.3. THERMAL CONTROL......................................................................................... 44
10.4. MIRRORING OF DATA....................................................................................... 44
10.5. MAINTAINABILITY.............................................................................................. 44

11. UPGRADIBILITY .........................................................................................45
12. TARGET ADMINISTRATION.......................................................................46
12.1. PASSIVE MONOITORING.................................................................................. 46
12.2. ACTIVE MONITORING....................................................................................... 46

13. MULTI MONITORING SETUP.....................................................................47
13.1. PASSIVE MONITORING..................................................................................... 47
13.2. ACTIVE MONITORING....................................................................................... 47

14. DOCUMENT REVISION HISTORY .............................................................48
Siemens MC General Product Description V2.3.doc Page 4 of 48
Copyright © Siemens AG 1999, 2000
ICM CD IS (Information Security)

Table of Figures

Figure 2­1: Active Monitoring: Connection MC into the Communication Network................ 6
Figure 2­2: Passive Monitoring: Connection MC into the Communication Network............. 7
Figure 3­1: High level design ............................................................................................... 11

Figure 3­2: Geographical Distribution .................................................................................. 12
Figure 4­1: Example of Front­End for passive monitoring .................................................. 14
Figure 4­2: Example of Front­End for active monitoring ..................................................... 20
Figure 4­3: Dual Route Interface (DRI)................................................................................ 21
Figure 4­4: Single Route Interface (SRI) ............................................................................. 22
Figure 5­1: Monitor Center Back­End.................................................................................. 26
Siemens MC General Product Description V2.3.doc Page 5 of 48
Copyright © Siemens AG 1999, 2000
ICM CD IS (Information Security)

1. SCOPE

1.1. IDENTIFICATION
This document contains the general product description of the Siemens Monitor Center.
This Monitor Center represents the second generation making use of variable modules
according to the different public communication networks (Front­Ends) and a common
module for all solutions (Back­End).

1.2. PURPOSE
The main purpose of this document is to describe the basic functionality of the Siemens
Monitor Center.
NOTE:
This document is subject to changes without prior notice.
It is intended for informational purposes only
Siemens MC General Product Description V2.3.doc Page 6 of 48
Copyright © Siemens AG 1999, 2000
ICM CD IS (Information Security)

2. DEFINITIONS

2.1. MONITOR CENTER
A Monitor Center (MC) refers to a physical installation used to intercept and record
information transferred over telecommunication networks in an endeavor to support
government agencies (Law Enforcement Agencies LEAs) in crime prevention and/or
intelligence gathering activities.

2.2. MONITORING
Monitoring refers to an intercept of speech and/or data exchanged between two or a
group of subscribers by a third party within a communication network.
Basically there are two possibilities in monitoring:
. Active Monitoring refers to the fact that the target (phone) numbers to be monitored
are marked from within the network. The Monitoring functionality is a built in function
of the “Switch”. For monitoring purposes, only targeted phone calls are routed to the
MC. This can be compared with a three party conference call, in which the MC is a
silent member of the conference call. Active Monitoring plays an active role in the
communication network, in the sense that the Monitor Center is viewed as a
subscriber to the network with a certain service level. Lawful Interception is an
example for Active Monitoring.
Figure 2­1: Active Monitoring: Connection MC into the Communication Network
GSM or PSTN
Switch
1)
X.25
Network

IRI
and
Marking
Intercept
Related
Information
(IRI) Terminal(s) for
and
handling of
Intercept Related
Information (IRI)
Administration
1) Monitoring Functionality in the switch must
be provided by the Operator/Switch Manufacturer
2) depending on the Operator/Switch­Manufacturer
2)

Monitor Center

MC FRONT­END MC FRONT­END
Switch Type Switch Type

MC BACK­END MC BACK­END
LAN

Speech/Data
transmission
Content of
Communication
(CC)
Siemens MC General Product Description V2.3.doc Page 7 of 48
Copyright © Siemens AG 1999, 2000
ICM CD IS (Information Security)

. Passive Monitoring refers to the fact that no target number information is kept inside
the network. Connection is made i.e. to trunk lines via high impedance coupling
devices between switches. The database of target numbers is administered inside the
MC. The Monitor Center, therefore, plays a passive role in the communications
network. A large number of trunks are thus monitored with typically only a few calls
being selected for recording at any moment.
Within the Siemens Monitor Center there is distinguished between the two Monitor Center
applications merely by a difference in the Front­End.
Figure 2­2: Passive Monitoring: Connection MC into the Communication Network
Monitor Center

MC FRONT­END MC FRONT­END
Trunk

MC BACK­END MC BACK­END
GSM or PSTN
Switch
LAN
= Coupling Devices
Complete Trunk Groups
Switch
Siemens MC General Product Description V2.3.doc Page 8 of 48
Copyright © Siemens AG 1999, 2000
ICM CD IS (Information Security)

2.3. GENERAL DEFINITIONS

BRI
Basic Rate Interface
Call
Any connection capable of transferring information between two or more users of a
telecommunications system. In this context a user may be a person or a machine.
Call Content (CC)
The information exchanged between two or more users of a telecommunications service,
excluding intercept related information.
Call Related Data (CRD) / S­Record / LI­Record / Intercept Related Information (IRI)
A collection of information or data associated with telecommunication services involving
the target identity, specifically call associated information or data (e.g. unsuccessful call
attempts), service associated information or data (e.g. service profile management by
subscriber) and location information.
CLIP (Calling Line Identification Presentation)
CLIP is an ISDN authentication feature. The number of the calling party is present for the
called party.
COLP (Connected Line Identification Presentation)
COLP is an ISDN authentication feature. The number of the called party is present for the
calling party. So it would be possible to notice call forwarding to another target.
CUG (Closed User Group)
CUG is an ISDN authentication feature. A group of users restricted there usage of the
network to communications inside the group.
Dossier
The term Dossier refers to all interceptions / intercepts relating to a specific monitored
target or targets. A dossier is a collection of intercepts for a specific set of monitored
target(s). It typically serves as evidence in a court case and represents all the Calls made
by the target(s) involved in the court case that was monitored.
Siemens MC General Product Description V2.3.doc Page 9 of 48
Copyright © Siemens AG 1999, 2000
ICM CD IS (Information Security)

DRI (Dual Route Interface) / Standard Interception
The Call Content and the Call Related Data, of an interception, are transmitted to the
Monitor Center via two physically separated interfaces.
Intercept
Call Content or Call Related Data of a monitored target.
Interception
The action, performed by an access provider / network operator / service provider, of
making available certain information (Call Content and Call Related Data) of a marked
target and providing that to the Monitor Center.
Intercept event
An intercept event is generated based on a recording activity from the recording side (MC
Front­End) and is sent to the common MC Back­End. It contains all relevant information or
references to information about the intercepted communication.
IRI
Intercept Related Information. A collection of information or data associated with
telecommunication services involving the target identity, specifically call associated
information or data (e.g. unsuccessful call attempts), service associated information or
data (e.g. service profile management by subscriber) and location information.

Law Enforcement Agency (LEA)
An organization authorized by a lawful authorization based on a national law to request
interception measures and to receive the results of telecommunications interceptions.
LI
Lawful Interception
PRI
Primary Rate Interface
Split Stereo
The two different directions of a telephone communication are transmitted to the Monitor
Center via two mono calls.
Siemens MC General Product Description V2.3.doc Page 10 of 48
Copyright © Siemens AG 1999, 2000
ICM CD IS (Information Security)

SRI (Single Route Interface) / Switch Feature, Restricted Interception
The call content and the call related data, of an interception, are transmitted to the Monitor
Center via one physical interface.
SUB
ISDN Subaddressing.
Target
A person or persons, specified in a lawful authorization, whose telecommunications are to
be intercepted.
Target Administration
Marking of targets (subscribers, triggers), e.g. enter new interception decision.
Siemens MC General Product Description V2.3.doc Page 11 of 48
Copyright © Siemens AG 1999, 2000
ICM CD IS (Information Security)

3. DESIGN OVERVIEW
A primary goal of the design of the Monitor Center system was to find as much commonality
between Active Monitoring and Passive Monitoring as possible, as well as to integrate
different switch types or networks into one solution. This document describes the common
parts of the products.

3.1. HIGH LEVEL DESIGN
The purpose of a Monitor Center system is to intercept communication, organize
intercepts and facilitate access to, and processing of intercepts.
The Siemens Monitor Center is divided into two parts:
. The Monitor Center Front­End is specific to the type of application (Active or Passive
Monitoring) and contains the devices used to capture intercepts. Examples of such
devices are PCM recorders and devices that intercept packet data. The function of the
MC Front­End is to capture (record) intercepts and information about intercepts. The
Front­End for active monitoring can also be specific according to the switch type, that
is connected to the MC.
. The Monitor Center Back­End is common for all Active and Passive Monitoring
applications. It handles the processing of intercepts. It is not involved in the recording
of intercepts, but receives intercept events in a common format and collects
(stores/archives) the intercepts from different types of Front­Ends.
The Siemens Monitor Center Back­End can handle more than one Front­End at the
same time.
Figure 3­1: High level design
Switch Type 1

MC BACK­END MC BACK­END
Trunk Lines

MC FRONT­END
Switch Type 1 Switch Type 1

MC FRONT­END
Switch Type n Switch Type n

MC FRONT­END
Trunk Lines Trunk Lines

Monitor Center
Monitoring
Interface

Switch Type n

..... .....

active passive active
Monitoring
Interface
Monitoring
Interface

Siemens MC General Product Description V2.3.doc Page 12 of 48
Copyright © Siemens AG 1999, 2000
ICM CD IS (Information Security)

3.2. GEOGRAPHICAL DISTRIBUTION
The Monitor Center may be distributed over a number of sites (physical locations). This is
true for the geographical location of any of the organizational sub structures.
The following figure shows the possible distribution of a generic Monitor Center in order to
illustrate the different locations of subsystems.
Figure 3­2: Geographical Distribution
In most cases the Monitor Center will be situated at one physical site and serves a single
LEA but different local groups within the LEA. However the Monitor Center can also be
distributed over a number of sites. These sites could be for housing of different LEAs or
LEA groups or access points to the transmission media (a mechanism which passes
information between a network operator or service provider and a Monitor Center).
The Siemens Monitor Center uses TCP/IP as transmission protocol, which enables LAN
as well as WAN applications. LAN support exists for 10 Mbps and 100 Mbps Ethernet.

Communication Network
MC1 / LEA1
Front­End
Back­End
Remote
Access
LEA1­group
MC2 / LEA2
Front­End
Back­End
Remote
Access
LEA2­group
LAN/
WAN

LAN/
WAN
Siemens MC General Product Description V2.3.doc Page 13 of 48
Copyright © Siemens AG 1999, 2000
ICM CD IS (Information Security)

4. MONITOR CENTER FRONT­END: GENERIC
The function of the Front­End is to capture intercepts and relay intercept events to the MC
Back­End. In telecommunication monitoring the Front­End could be a digital or analogue
interface. In packet data networks the Front­End could include a device to capture data
packets, email messages, etc.
These intercept events are relayed to the MC Back­End via an Event Interface. The Back­
End detects the events and manages it accordingly.
Fax and Data detection is performed on the Front­End and a 64 kbit/s recording is started
automatically. Standard fax detection is performed based on the 2100 Hz answer (pilot) tone
within a fax transmission. The tone may occur anywhere within a recording. Faxes may also
be identified by detecting the ISDN type of service. If the type of service is available, and it
identifies the call as a fax transmission, the intercept is marked as such and this implies a
64 kbit/s recording. Detection and Recording of data is performed in the same manner.
For passive monitoring applications that include the DVX switching multiplexer, also
enhanced fax/data detection algorithms based on the modulation itself are available.
Siemens MC General Product Description V2.3.doc Page 14 of 48
Copyright © Siemens AG 1999, 2000
ICM CD IS (Information Security)

4.1. FRONT­END: PASSIVE MONITORING
In Passive Monitoring applications (e.g. for international trunk lines) telecommunication
transmission lines are monitored passively. The connection to these lines is normally done
via high impedance coupling devices.
Signaling supported by different Passive Siemens Monitor Center Front­Ends:
. SS7 ISUP/TUP
. R1
. R2
. No. 5
. Analogue lines
. E1 without signalling
The validity of the signal frame (HDB3) can be checked on the recorder and errors are
then reported via alarm functions.
. ISDN PRI and ISDN BRI (EDSS1)
The following passive protocols are considered for implementation:
. T1 without signalling
see E1 without signalling
. ISDN (USA)
. POTS
Acquisition Unit
Acquisition Unit

Coupling Devices
signalling
timeslots

DVX

CCS7 ISUP
LAN

to the Back­end

Front­End

AQ
CTRL
SVR
PA
Figure 4­1: Example of Front­End for passive monitoring
Siemens MC General Product Description V2.3.doc Page 15 of 48
Copyright © Siemens AG 1999, 2000
ICM CD IS (Information Security)

4.1.1. Passive Monitoring Front­End components
4.1.1.1. Acquisition Units, Recorders (AQ)
The Acquisition Units (AQ), shortly referred to as the “Recorders” will store the
targets communication contents (like speech or data traffic) as well as additional
data that is necessary and valuable to identify and analyse the recorded information.
The Recorder is equipped with digital PCM E1 interfaces that connect to the PCM
outputs of the DVX Multiplexer. The recordings are stored on harddisk for immediate
and direct on­line access and are handed over (copied) to the MC Backend for
centralised storage and archiving.
One Acquisition Unit can handle up to 60 channels simultaneously. According to the
requirements, one Front­End can consist of several Acquisition Units.
Acquisition Unit
Siemens MC General Product Description V2.3.doc Page 16 of 48
Copyright © Siemens AG 1999, 2000
ICM CD IS (Information Security)

4.1.1.2. DVX – Switching Multiplexer
The Monitor Center connects to digital streams via the DVX switch. CAS signalling
on these trunks is directly processed on the DVX in order to determine important
information such as the originating and destination addresses of the communicating
parties. It also analyses the signal to determine fax/data communication. This
information is essential for recording decisions.
Switching of intercepts through to recording equipment is based on rules and
attributes, which are configurable. This is a function of the Recording Controller
which also holds a trigger table for the targeted communication activities.
In the case of SS7 signalling, the timeslots bearing signalling information (signalling
links/link sets) are switched to an external protocol analyser which performs the
signalling analysis.
Siemens MC General Product Description V2.3.doc Page 17 of 48
Copyright © Siemens AG 1999, 2000
ICM CD IS (Information Security)

4.1.1.3. Protocol Analyser (PA)
The Protocol Analyser (PA) for SS7 signalling (ISUP and/or TUP) decodes the
signalling information that is switched through by the DVX. The PA allows to be
configured according to the configuration that is used within the signalling network,
i.e., the definitions of load sharing groups/signalling link sets, the signalling point
codes of the exchanges that have to be included into the monitoring as well as
necessary mapping functions for the PCM numbers and timeslots (CIC (Circuit
Identification Code) mapping) to reference logical and physical numbering of both
the communication links and the DVX inputs. The PA has a graphical user
interfaces to allow configuration, testing and supervision of the signalling analysis.
Once configured, the PA runs on ist own as a “black box”. The decoded signal

information is sent via LAN to the Recording Controller that controls switching of the
multiplexer and recording on the Acquisition Units accordingly.
Siemens MC General Product Description V2.3.doc Page 18 of 48
Copyright © Siemens AG 1999, 2000
ICM CD IS (Information Security)

4.1.1.4. Recording Controller (CTRL)
The Recording Controller is the heart of the Front­End system. In a trigger table it
keeps all definitions of the targets, continuously compares them with the actually
decoded signalling information from either the DVX (CAS signalling or other activity
indication) or the Protocol Analyser (SS7) and – when the signalling information
meets one of the target definitions – switches the appropriate channel(s) from the
DVX inputs to a predefined output that is connected to the recording equipment.
The Controller also starts and stops the recorders and provides them with additional
information (extracted from the signalling) which is also being stored together with
the recording.
For each recording activity it generates intercept events that are sent to the Back­
End and entered into the central database.

4.1.1.5. Supervisor Station (SVR)
The Supervisor Station is a WIN NT based Desktop PC and can be used to mark
subscriber in a passive monitoring scenario. The Supervisor can only be used by
CAS signalling, SS#7 is not supported. The use of a supervisor is advisable if
beside trunk monitoring also a Siemens EWSD active monitoring Frontend is
necessary because the Supervisor is also capable to do the monitoring
administration (marking of subscribers) of one or more EWSD switches (see
5.2.2.1).
Siemens MC General Product Description V2.3.doc Page 19 of 48
Copyright © Siemens AG 1999, 2000
ICM CD IS (Information Security)

4.2. FRONT­END: ACTIVE MONITORING
4.2.1. General
In Active Monitoring applications, also referred to as subscriber monitoring, active
connections (call setups) are established to the Monitor Center and Intercept Related
Information (IRI) may be routed via a single route interface (SRI) or a dual route
interface (DRI). Additional descriptions of the two interfaces are as follows:
. Single Route interface (SRI) entails that call related information is passed through the
same link as the call content.
. Dual Route Interface (DRI) entails that call related information is passed through a
different link than the call content.
Both of the above interfaces are supported by the Monitor Center.
The Front­End is designed to provide a multi­vendor­capability this allows an easy
adaptation of other interfaces from different Switch Manufacturers.
Signalling supported by different Active Siemens Monitor Center Front­Ends:
ISDN / EDSS1 (PRI, BRI)
R2D
In the case of EDSS1 CUG, COLP, CLIP and SUB are supported in order to
authenticate the Monitor Center.
The following active protocols are considered for implementation:
T1
ISDN (USA)

POTS

Siemens MC General Product Description V2.3.doc Page 20 of 48
Copyright © Siemens AG 1999, 2000
ICM CD IS (Information Security)

Figure 4­2: Example of Front­End for active monitoring

MC MC
FRONT­END FRONT­END
CC­ Interface
EDSS1 S2M

Acquisition Unit
Call Controller IRI Controller
(S­Record Controller)

Terminal for

Switch

Intercept Related
Information (IRI)
and
handling of
Intercept Related
Information (IRI)

X.25

Administration LAN

X.25

MC­Back­End
Intercept Event
Interface
Intercept Contents
Interface

Siemens MC General Product Description V2.3.doc Page 21 of 48
Copyright © Siemens AG 1999, 2000
ICM CD IS (Information Security)

4.2.1.1. Dual Route Interfaces (DRI)
Calls are established to the Front­End using R2D­MFC or EDSS1 signalling, for the
transmission of the Call Content of an intercept. The signalling information is
extracted, and a Recording Controller makes the decision to record, switches the
Call to a recorder, starts recording and passes an event to the Back­End.
S­Records (Intercept Related Information) pertaining to the intercept are received
via a separate interface (X.25) and passed to the Back­End as an event. In the
Back­End the S­Record and Call Content are correlated. S­Records that cannot be
correlated to a recording will be stored in a temporary location for manual
association.
Figure 4­3: Dual Route Interface (DRI)
Call Content
Intercept Related
Information
S­Record DRI

Front­End
Siemens MC General Product Description V2.3.doc Page 22 of 48
Copyright © Siemens AG 1999, 2000
ICM CD IS (Information Security)

4.2.1.2. Single Route Interface (SRI)
Calls are established to the Front­End using R2D­MFC or EDSS1 signaling. The
signaling information is extracted, and a Recording Controller makes the decision to

record, switches the call to a recorder, starts recording and passes an event to the
Back­End.
In the case of EDSS1 additional intercept related information is received via
subaddress fields. In the case of R2D in­band MFC may also be used to transfer
additional information.
Figure 4­4: Single Route Interface (SRI)

4.2.2. Statistical Monitoring
In certain cases only Intercept Related Information are received without any Call
Content. This is also referred to as statistical monitoring.
Call Content + Intercept
Related Information

SRI

Front­End
Siemens MC General Product Description V2.3.doc Page 23 of 48
Copyright © Siemens AG 1999, 2000
ICM CD IS (Information Security)

4.2.3. Active Monitoring Front­End components
4.2.3.1. Acquisition Unit
The Acquisition Units, shortly referred to as the “Recorders” will store the Intercept
Data (like speech or data traffic) as well as additional data that is necessary and
valuable to identify and analyse the recorded Intercepts. The Recorder is equipped
with digital PCM E1 interfaces connected to the PCM stream delivered from the
relevant switch (communication network). The recordings are stored on harddisk for
immediate and direct on­line access and are retrieved (copied) from the MC Back­
End for centralised storage and archiving.
One Acquisition Unit can handle up to 60 channels simultaneously. According to the
requirements, one Front­End can consist of several Acquisition Units.
Acquisition Unit
Siemens MC General Product Description V2.3.doc Page 24 of 48
Copyright © Siemens AG 1999, 2000
ICM CD IS (Information Security)

4.2.3.2. Call Controller (CC)
The CC is based on WIN NT. It is controlling the call set­up and call clear down of the
Acquisition Unit on the interface to the switches (E1, S2m or So) and transmits the
start/stop command to the predefined recorders. The CC distinguishes the incoming
call set­up between voice data and fax/modem data. If the incoming call set­up is a
voice transmission, the CC switches to a predefined compression algorithm (e.g
24 kbit/s). If the incoming call set­up is a fax/modem transmission, the CC switches
over to record the data with 64 kbit/s for later decoding purposes.
For each call it creates an Intercept Event. These Intercept Events contain all
available information and are sent to the Back­End to inform about the incoming calls.
An entry is written to the MC Database and the information is visible to the user of the
Unified User Station.

4.2.3.3. S­Record­Controller (LI­Rec.­Contr.)
The S­Record­Controller is based on WIN NT. It receives Call Related Data via
X.25 / X.31 or LAN and passes the event to the Back­End for interpretation. In the
Back­End the S­Record is correlated to the accompanying call and can be viewed
from the Unified User Station. The type of S­Record is indicated as a Start­, Stop­ or
Continue – Record. Multiple S­Record Controllers may exist within the same system

(Multi­Vendor­Capability, performance reasons).

Siemens MC General Product Description V2.3.doc Page 25 of 48
Copyright © Siemens AG 1999, 2000
ICM CD IS (Information Security)

5. MONITOR CENTER BACK­END
One MC Back­End can handle several Front­Ends at the same time.
The MC Back­End receives intercept events from the Front­End(s). It’s function is to
organize intercepts into Dossiers and control access to and processing of intercepts,
following the Dossier principles.
A Dossier is a collection of intercepts, that is logically belonging to one case under
investigation. This can be all intercepts of one target or of more targets, involved in the same
case.

5.1. BACK­END FUNCTIONALITY
5.1.1. Dossier based administration:
The Administrator of the Monitor Center is creating a Dossier, by assigning a target
telephone number(s) or incoming lines of the Monitor Center to it. Additionally he gives
access rights to one or more investigators (see section “Management Station / Supervisor”
for more details).

5.1.2. Dossier based archiving of intercepts:
If so configured, all intercepts of one Dossier are archived together on one or more dossier
specific archiving mediums (if one is not enough) without mixing them with other Dossiers. If
required, also mixed archiving onto the same media is possible.

5.1.3. Dossier based access to the intercepts:
An operator / investigator logging into the system via an operator station (Unified User
Station) will only gain access to those Dossiers he is allowed to, i.e. those Dossiers he had
been granted access by a system manager/supervisor.

5.1.4. Hot / On­line Monitoring:
The Back­End allows access to intercepts from an Operator Station as soon as the recording
is started. Hot­/On­line monitoring can be done selectively as each operator can subscribe
individually to those activities he is interested in for hot­monitoring. The playback will take
place in quasi real time with a slight delay due to data processing and network throughput
(typically 2 to 5 sec)
Siemens MC General Product Description V2.3.doc Page 26 of 48
Copyright © Siemens AG 1999, 2000
ICM CD IS (Information Security)

5.1.5. Processing of intercepts:
Processing of intercepts means playback, transcription, Fax and Data Demodulation etc.
(see later sections for more details).

5.2. BACK­END COMPONENTS
5.2.1. Principle Overview
Figure 5­1: Monitor Center Back­End
Figure 5­1 shows a principle overview of a typical MC Back­End and its main functional
components.
The physical layout of a real system may differ in the number of components as well as in the
applications that run on the components. The system applications are normally not physically
bound to a dedicated PC hardware. They may run together or in certain combinations on one
PC or each application might run on its own PC.
The final system layout will depend on customer requirements, the overall system size

(number of input lines, storage capacity, etc.) and necessary performance.
MC Database

Central Database

MC MC
BACK­END BACK­END
Unified User Station(s)

(Playback/View Intercepts,
Hot Monitoring)

MC­Dossier Storage

Central Storage System

MC Manager

Administration of Users /
Dossiers / Access rights

MC Controller
Central Control
Tasks LAN

FAX/Data­
Demodulation
Subsystem
Intercept Event
Interface
Intercept Contents
Interface

Siemens MC General Product Description V2.3.doc Page 27 of 48
Copyright © Siemens AG 1999, 2000
ICM CD IS (Information Security)

5.2.2. Management Station / Supervisor Station for EWSD
5.2.2.1. Supervisor Station for EWSD
The Supervisor Station is a WIN NT based Desktop PC. It is a typical component for
active monitoring applications and is connected via X.25 to the Siemens EWSD
switches via dial back modem. The Supervisor provides all necessary MML
commands to administer the Monitoring Function of the EWSD (marking of Targets).
The connection is only established as long as this is required for the transmission of
the Monitoring Commands. This allows the administration of more than one EWSD
(unlimited). Please note, that the Supervisor can interact directly with the EWSD via
X.25 modem. On each EWSD site an adequate X.25 modem and a PAD (Packet
Assembler / Disassembler) is necessary. An alternative is the connection of the
Supervisor to the OMC (DCP).

5.2.2.2. Dossier Administration / MC Manager
A Dossier may consist of a list of telephone numbers, which is used by the
person(s) under investigation. Depending on the type of application, a dossier
alternatively (or additionally) may also consist of a list of incoming channels to
the Monitor Center. In this case all data received on specific channels therefore will
be stored in a Dossier.
¾ Create Dossier
Dossier based configuration is possible from a Management Station / Supervisor
which allows an Administrator to create dossiers and create access rights to
these dossiers. The Management Station may also be connected to the system
via a Wide Area Network (WAN).
Siemens MC General Product Description V2.3.doc Page 28 of 48
Copyright © Siemens AG 1999, 2000
ICM CD IS (Information Security)

¾ Modify/View/Delete Dossier
A Dossier can also be modified, viewed or deleted. Functionality includes the

specification of target numbers as well as which operator/operator groups have
access to it.
¾ Unambiguous Content of Dossiers
Unique reference numbers are associated to Dossiers and all intercepts and
associated data are identified using this number.
¾ Create/Modify/Delete Operator Group and Operators
Operators and operator groups consisting of several operators can be created.
Operators and Operator Groups are given access to specific Dossiers.
Access rights include the right to view, listen, delete intercepts.
¾ Storing/Archiving Criteria
Archiving criteria refers to whether one of the following criteria should be followed
when archiving:
. Archive all the intercepts
. Archive marked intercepts only
Siemens MC General Product Description V2.3.doc Page 29 of 48
Copyright © Siemens AG 1999, 2000
ICM CD IS (Information Security)

5.2.3. MC Controller (MCC)
High performance PC running Windows NT Server.
The MC Controller server is one of the main components that runs basic control and
management applications. The two major applications normally run on the MCC are:
The Intercept Manager (IM) is the interface for the messages from the Front­End(s) to
the Back­End. It receives the intercept events and stores this information in the Central
Database. Its main task is to correlate intercept events to the related dossiers and to
also correlate intercept events that belong to the same intercept, e.g. the events for the
Call Content and the Intercept Related Information.
The Monitor Center Controller (MCC) application manages and controls the handling
and possible post­processing of all intercepts and related information. Amongst others
it controls storing, deletion and demodulation.
Siemens MC General Product Description V2.3.doc Page 30 of 48
Copyright © Siemens AG 1999, 2000
ICM CD IS (Information Security)

5.2.4. MC Database

High performance PC running Windows NT Server.
The MC Database server contains the central database of the Monitor Center Back­
End. As standard MS SQL Server is used.
The database consists of several basic tables that contain:
­ configuration parameters
­ the definitions for dossiers, users, groups
­ the definitions for triggers
­ rights definitions
It also holds the Dossier Database, the intercept information and the references to
information stored outside the database.
It is basically organized into
­ Dossier specific tables containing the main intercept entries
­ Intercept specific tables that contain information about the attachments that belong
to an intercept (like a speech recording, a transcription, a decoded fax, etc.) and
the pointer/locator to the place, were the attachment is actually stored.
­ Dossier specific configuration for rights, storage and archiving.

Siemens MC General Product Description V2.3.doc Page 31 of 48
Copyright © Siemens AG 1999, 2000
ICM CD IS (Information Security)

5.2.5. Storage System / Dossier Storage
High performance PC(s) running Windows NT Server.
The Storage System layout is highly depending on the system requirements,
storage/archiving capacity, number of dossiers, etc. It may therefore consist of several
units with several tasks and configuration.
A Storage System can basically be divided into two logical components:
­ Storage Controller, a process that manages and controls Storage Units. Depending
on the system size, this component may run on a separate or the same machine
that runs Storage Unit(s). It offers intercept retrieval services and moves intercepts
from the Front­End to storage unit(s).
­ Storage Unit(s), that consist of storage/archiving volumes. A Storage Unit may
consist of several archiving volumes in one unit or may only contain one volume in
one unit. It provides a device independent volume interface to the Storage
Controller. All device specific functions are hidden in the Storage Unit.
A Volume is a storage media. It can be a magneto optical disk (MOD) platter, a
digital audio tape (DAT), a RAID, or a single disk drive (harddisc).
The solution for Dossier storage is to use discreet drives for each storage volume. The
storage units consists of NT based machines which can have up to 8 discreet
volumes. The volumes may be harddisk drives (optional with RAID), Magneto Optical
Drives (MOD) or DAT drives. The dimensioning of the volumes (archiving capacity) is
according to the requirements.
In special situations, one MOD platter can be used as a working storage medium while
a second one is used as a master copy (proof medium). †
An important feature of the Storage Unit is that each platter is permanently mounted on
a drive. There is thus one drive per platter and platters are not swapped in and out of
drives under software control.
† 

Available on special request

Siemens MC General Product Description V2.3.doc Page 32 of 48
Copyright © Siemens AG 1999, 2000
ICM CD IS (Information Security)

This has the following major advantages:
. Speed: Having one drive per platter means that the platter is always mounted and
data can be read and written continuously without ever having to wait for a platter to
be swapped in.
. Reliability: No jukebox robot swapping mechanism is needed, which eliminates a
major source of unreliability.
. Throughput: A limited number of volumes are connected per Storage Unit. As
more Dossiers are needed, more Windows NT servers with optical drives are
added, but each new Storage Unit can handle the maximum data traffic required
and the optical storage never becomes a throughput bottleneck as would be the
case of one centralized jukebox.
The whole system may be configured to consist of one Dossier, which implies that all
intercepts will be stored on one virtual volume. In the case of Lawful Interception one
volume may be allocated to one Dossier. Archiving of intercepts will be performed
automatically.
The archived information is stored in standard file formats as there are WAVE format

for audio files (speech), TIFF format for decoded fax images, TEXT format for log­files,
transcriptions or text­based attachments like S­Records. Text formats include both
ASCII text and RTF format.

5.2.5.1. Export of data from Dossier Storage
Through the Unified User Station, discussed in more detail further on, data may be
exported from Dossier Storage to a local disk or e.g. a floppy disk.
Exported data will be saved in the standard computer formats as listed above.

5.2.5.2. Management of storage volumes
Storage volumes must be formatted before it can be used within the system. This is the
responsibility of the System Administrator. Unique volume labels with direct reference
to the relevant dossier as well as information uniquely identifying the volume are
provided for.
An indication in the form of an alarm informs the Administrator that a volume needs
replacement. Overflow is catered for but data cannot be overwritten in the case of a
storage volume reaching capacity. A volume may be disabled and replaced.
Automatic label printing for MOD and DAT‡.
‡ 

available in 2000

Siemens MC General Product Description V2.3.doc Page 33 of 48
Copyright © Siemens AG 1999, 2000
ICM CD IS (Information Security)

5.2.5.3. Restoration of data
Archived can be restored back to the system for on­line availability. If not existing
anymore in the system, the original dossier structure may be recreated during
restoration.
Siemens MC General Product Description V2.3.doc Page 34 of 48
Copyright © Siemens AG 1999, 2000
ICM CD IS (Information Security)

5.2.6. Operator Station / Unified User Station ( UUS )
The Siemens Unified User Station (UUS) software is a Windows NT based utility presenting
the operator with a view of intercepts associated with dossiers. The UUS software provides
the user with an Internet Browser similar look and feel. It enables the operator to access the
intercepts associated with the dossiers he has access to.
Typically, an operator logs into the system (with access only to the certain Dossiers) on an
UUS and is shown a list of intercepts associated with these Dossiers. Grouped under each
Dossier are intercepts, transcriptions, etc. associated with the Dossier. Each intercept has
status information associated with it that eases handling and processing by an operator, e.g.:
. Untouched (new)
. Touched (e.g. played )
. Transcribed
. Storing/stored, demodulating/demodulated, etc.
This information is obtained from the Monitor Center Database.
Siemens MC General Product Description V2.3.doc Page 35 of 48
Copyright © Siemens AG 1999, 2000
ICM CD IS (Information Security)

5.2.6.1. Playback

On selecting an intercept that contains a speech recording a graphical playback
window provides for playback control. Depending on the type of recording, playback
might be either in mono or stereo.
Basic playback functions:
. Start

. Pause
. Rewind
. Fast forward (can be configured to jump in relative steps)
. Fast backward (can be configured to jump in relative steps)
. Playback cursor might be freely positioned directly at any position in the recording
. Window shows start and stop time and actual playback position
. The playback position can be shown as either an absolute or relative time value
. A portion of the recording might be marked for looped (repeated) playback
. Variable playback speed: ½ to 2 times real speed without pitch change
. Transcription during playback
. Often used functions also available via shortcut keys

5.2.6.2. Hot / On­Line Monitoring
While logged in, an operator may be notified of a high priority call that is just being
recorded and by clicking on the notification, hot­monitoring playback may be done while
recording is still in progress.
Hot­monitoring for a certain target will already be defined during target/trigger definition.
If such target becomes active, a hot­monitoring alarm is broadcasted. Each operator
having access rights to activities of that target can individually subscribe to receive these
hot­monitoring alarms. This also can be done for each dossier individually. Hot­monitoring
alarms will show up in a separate window on the UUS.
As soon as an operator receives such an alarm, he immediately can start hot­monitoring
that activity. In the case of split stereo the operator may listen to one or both channels
depending on what is immediately available. The source of the recording will be the
recorder and not the Dossier Storage. An inherent delay of 3­4 sec. is present because of
hardware buffering.
The system is able to handle incoming calls/recordings while operators are listening and
viewing intercepts from their UUS. This, however, will be the case within certain physical
restraints such as processing speed and network bandwidth.
Siemens MC General Product Description V2.3.doc Page 36 of 48
Copyright © Siemens AG 1999, 2000
ICM CD IS (Information Security)

5.2.6.3. Fax Display

Provided that the Monitor Center is equipped with an optional Fax or Fax/Data
demodulation system, recordings successfully demodulated and decoded will be
available as a TIFF image file for direct viewing.
Using the built­in fax viewer, a fax image can be displayed, swapped, flipped, and
zoomed via the Unified User Station.
It is also possible to configure the UUS to use an external fax viewer as default viewer.
Thus special customer requirements can easily be satisfied.
Additional information pertaining to a fax (like modes, formats, etc.), will be stored in a
text file that can be viewed with the built­in editor.

5.2.6.4. Transcription
It is possible to transcribe the recording into a word processor while listening to the
recording. Transcription software packages supported currently are:
. Built­in TXT editor
. built­in RTF editor
. as default configurable external editor (e.g. Microsoft Word or Wordpad).
External editor – if not part of the operating system – is optional.

Siemens MC General Product Description V2.3.doc Page 37 of 48
Copyright © Siemens AG 1999, 2000
ICM CD IS (Information Security)

5.2.7. Fax and data Demodulation
A system for Fax/data­Demodulation can be offered separately.
Once a fax or data transmission has been recorded and transferred to the Storage
System, it must be demodulated and decoded to be able to display it. This is done by
the Siemens Fax Demodulator or by the Fax/Data Demodulation System. Only
transmissions recorded at 64 kbit/s can be decoded successfully. After demodulation
and decoding it is saved back to the Storage System from where it may be viewed.
Many Fax equipment manufacturers are not following the standards. They make use of
proprietary protocols for Fax transmissions between their equipment. Therefore, the
Fax/Data Demodulation System is also able to demodulate more than 1000 nonstandard
Fax protocols from different manufacturers. Please note, that some Faxes
from no­name Fax machines might not be demodulated. A list of Fax machine
manufacturers that are supported can be provided on demand.

5.2.7.1. Siemens Fax Demodulator
The optional Fax Demodulator (using the Siemens Fax Demodulation software) has the
functionality to demodulate identified fax transmissions stored on the Storage System.
Such transmissions are retrieved from Dossier Storage, demodulated, decoded and
stored on the Dossier Storage in the form of viewable .TIF documents.
The Siemens Fax Demodulator is a Win32 system that runs on a high speed Windows
NT platform. It demodulates standard G3 Faxes at about three times of the real
speed. These units need to be operated in parallel in situations where large numbers of
faxes must be handled.
Siemens MC General Product Description V2.3.doc Page 38 of 48
Copyright © Siemens AG 1999, 2000
ICM CD IS (Information Security)

5.2.7.2. Fax/Data Demodulation System
This optional System consists of special hardware and software and can demodulate
Fax and Data transmissions. More than 1000 non­standard Fax protocols from different
manufacturers are supported.
Information on the training phase is extracted and stored for later analysis. This
information includes the following:
. Handshake information
. Manufacturer of the fax equipment
. Type of coding (error Correction Mode, etc.)
Also Internet data transmissions between a subscriber (target) and the Internet
provider can be demodulated and viewed. This allows the LEA to monitor and view the
Internet session of the target (offline), like the target saw it online, except session
activities of the target which did not result in a communication activity (i.e. use of
data/programs already active in computer cache memory).
For further information please ask for separate document.
Siemens MC General Product Description V2.3.doc Page 39 of 48
Copyright © Siemens AG 1999, 2000
ICM CD IS (Information Security)

5.2.7.3. Manual or automatic data analysis
If Fax/data demodulation equipment is part of a Monitor Center the system can be
configured for automatic demodulation of all fax/data transmissions (recognized and

marked as such).
It is also possible to demodulate and decode transmissions on request, i.e., the
operator can decide, which intercept shall be demodulated.
The second possibility might be helpful, when only limited demodulation capacity is
available or to force a demodulation for an intercept that was not recognized
automatically as a fax or data transmission during recording.
Siemens MC General Product Description V2.3.doc Page 40 of 48
Copyright © Siemens AG 1999, 2000
ICM CD IS (Information Security)

6. ALARMS

Alarm conditions may occur throughout the Monitor Center and its individual components.
Alarms can be handled in a number of ways.
Alarms of all components are provided as far as possible centrally. The system runs an
Alarm Server that receives alarms from the system components and broadcasts them on the
LAN.
Alarm Viewers can be installed anywhere in the system (e.g. on Management or Operator
Stations) and each Alarm Viewer can be configured individually to listen only to certain or to
all alarms, i.e., each specific alarm can be "subscribed" for.
Each alarm subscription can be defined individually to generate an audible alarm, to only
create an entry in the alarm list or to pop­up an alarm window.
Siemens MC General Product Description V2.3.doc Page 41 of 48
Copyright © Siemens AG 1999, 2000
ICM CD IS (Information Security)

7. EVENT LOGGING
Every event in the Siemens Monitor Center can theoretically be logged.
It is widely possible to specify which events should be logged. These logs can be viewed for
analysis of activities or identification of possible bottlenecks and problems.
Siemens MC General Product Description V2.3.doc Page 42 of 48
Copyright © Siemens AG 1999, 2000
ICM CD IS (Information Security)

8. MC SECURITY

8.1. DOSSIER STORAGE FILE SECURITY
The security of data stored in the MC Back­End is based on NT security. Standard NT
group and user rights control access to files stored in the Storage System.

8.2. DATABASE SECURITY
Access to the database is allowed through interfaces, which relies on NT security. Any
person or process without sufficient user rights access will be denied.

8.3. PHYSICAL SECURITY
Password security is based on the NT security model which include:
. Minimum length passwords
. Password history
. Validity period of passwords are specified
. Unsuccessful logins limited
In cases where operators access the system from remote sites, third party authentication
and security techniques may be used such as dial­back, encrypted links, etc..
Third party products for additional physical security may also be used, like chip card
readers for access. They will not influence the system operation.
Siemens MC General Product Description V2.3.doc Page 43 of 48
Copyright © Siemens AG 1999, 2000

ICM CD IS (Information Security)

9. SCALABILITY
The Monitor Center is scaleable from a small system consisting of a single recording unit and
single Back­End Windows NT Server PC to a theoretically unlimited size.
The functionality is isolated into functional units. This allows for further scalability in the
system. Examples of such optional units are:
. New Front­Ends
. Fax/modem demodulation and decoding
. Extension of the Storage System
Siemens MC General Product Description V2.3.doc Page 44 of 48
Copyright © Siemens AG 1999, 2000
ICM CD IS (Information Security)

10. RELIABILITY
10.1. SYSTEM TIME

The system can optionally be time synchronized based on DCF77 (Europe) or GPS
(international). All sub­systems can be time synchronized. The recorders are
synchronized with an accuracy of 10 ms. This is essential in cases where split stereo
recordings are made on different recorders. All events are time stamped using the system
time.

10.2. POWER SUPPLY
. Support of UPS and automatic shutdown on detection of power loss (optional)
. Two power supplies, Hot Plug (optional)

10.3. THERMAL CONTROL
The CPUs in the recorders are continuously cooled by fan and the CPUs in the rack
mounted units are thermal controlled. In addition the racks are ventilated by forced air.

10.4. MIRRORING OF DATA
The design of a Siemens Monitor Center is flexible. Optionally it can be adapted to mirror
all essential data in the recorders and/or in the Back­End by RAID systems.

10.5. MAINTAINABILITY
The Back­End or components of it can be maintained and even switched off without
interrupting recording activity. Intercepts will be buffered on the recorders until the Back­
End is online again.
Siemens MC General Product Description V2.3.doc Page 45 of 48
Copyright © Siemens AG 1999, 2000
ICM CD IS (Information Security)

11. UPGRADIBILITY
Drivers and subsystems are developed in such a way as to allow for easy upgrades of
features and functionality.
It is possibility to upgrade the Back­End without interrupting recording activity. Intercepts will
be buffered on the recorders until the Back­End is online again.
Siemens MC General Product Description V2.3.doc Page 46 of 48
Copyright © Siemens AG 1999, 2000
ICM CD IS (Information Security)

12. TARGET ADMINISTRATION
12.1. PASSIVE MONOITORING
In case of passive monitoring the LEA has no direct access to the switch therefore the
marking of targets (Triggers) has to be done within the Siemens Monitor Center. Within
the MC Manager application there is a possibility to enter Triggers. These lists of Triggers

are automatically transferred to the Recording Controller of the passive Front­End. Based
on this Trigger information the Recording Controller decides which call has to be recorded
and therefore switches a certain input stream/channel to one available recording channel
on the AQ using the DVX.

12.2. ACTIVE MONITORING
The administration of marked subscribers, e.g. enter new interception decision, is done
using an administration workstation. In general there is no difference between
administration of a mobile or fixed network switch. In a fixed network it is only possible to
mark the telephone number of a subscriber whereas in a mobile network it is also possible
to mark IMSI, IMEI of a subscriber, if this feature is supported by the switch supplier.
Additionally it is possible to do a location based monitoring. This means all subscribers
temporarily located within a certain area (LAC) are monitored.
In order to send commands the administration workstation is connected via the X.25
network to the switches.Because of the roaming capability of mobile subscribers one
single subscriber has to be marked in each single MSC within a PLMN.

Administration
Workstation
Switch 1
X.25
Switch n

Admin command (switch n)
Admin command (switch 1)

Siemens MC General Product Description V2.3.doc Page 47 of 48
Copyright © Siemens AG 1999, 2000
ICM CD IS (Information Security)

13. MULTI MONITORING SETUP
Multi monitoring is necessary if more than one LEA want to use the monitoring functionality
within a telephone network, no matter if fixed or mobile network.

13.1. PASSIVE MONITORING
Passive monitoring also known as trunk monitoring is realised by tapping into the trunk
lines using high impedance coupling devices. If a second LEA also wants to monitor a
trunk line already under investigation by another LEA , a second coupling device has to
be installed at this particular trunk line. This has no influence neither on the administration
nor on the passive Front­End in the Monitor Center.

13.2. ACTIVE MONITORING
In case of active monitoring (this means a subscriber is directly marked within the switch)
one subscriber can be marked by more than one LEA simultaneously. In order to provide
all LEAs with the functionality of marking subscribers independently each LEA will have it’s
own remote terminal connected to one master administration workstation. It is assured
then that both LEAs will not see each other's marked targets on their remote terminals.
Also it will not happen that in case a target is deleted by one LEA it will also be deleted for
the other LEA.
For more than one LEA both Call Content (CC) as well as Intercept Related Information
(IRI) of an intercepted call has to be forwarded to all MCs having marked this particular
subscriber.
For the Call Contend the switch either mobile or fixed network has to multiply it and
forward the call to each MC. Depending on the supplier and software release of the switch
this functionality is built­in or additional hardware is needed.

Concerning the IRI the switch sends only one S­Record to the master administration
workstation (e.g. ICC, LIOS). The administration workstation duplicates the S­Record and
sends a copy to each MC having marked this particular subscriber.
Siemens MC General Product Description V2.3.doc Page 48 of 48
Copyright © Siemens AG 1999, 2000
ICM CD IS (Information Security)

14. DOCUMENT REVISION HISTORY
Revision Date Author

1.0 10/06/1998 Siegfried Neubauer PN KE IS PV
1.1 04/08/1998 Siegfried Neubauer PN KE IS PV
1.2 10/08/1998 Siegfried Neubauer PN KE IS PV
1.3 01/10/1998 Siegfried Neubauer PN KE IS PV
1.4 30/10/1998 Siegfried Neubauer PN KE IS PV
1.5 19/02/1999 Manfred Büttner ICP CD CT IS V
1.6 25/02/1999 Rumscheidt / Nissen ICP CD CT IS
2.0 04/03/1999 Nissen ICP CD CT IS
2.1 04/03/1999 Neubauer ICP CD CT IS
2.1.1 15/10/1999 Pörsch ICP CD IS
2.1.2 30/11/1999 Eisenschmid ICP CD IS
2.2 11/01/2000 Rumscheidt ICP CD IS S
2.2.1 09/02/2000 Büttner ICP CD IS S
2.3 12/05/2000 Büttner ICM CD IS S / Eisenschmid ICM CD IS PM

Copyright © Siemens AG 1999, 2000
All rights reserved. No part of this document may be reproduced or utilized in any form or any
means, electronic or mechanical, including photocopying, recording, or any information
storage or retrieval system, without permission in writing from the author.

Document Path: ["1104-siemens-product-description-monitoring-center.pdf"]